• THERMAL OIL HEATERS



    Used in zones where the supply of natural gas, gasoil or fuel oil is easy.



    They realize a warming of thermal oil in closed circuit.



    They yield heat for convection to consuming machines inside a productive process.
  • ELECTRICAL HEATERS AND BOILERS



    They contribute heat by means of electrical resistances of very low density.



    Performance of 100 % of the emaciated energy.
  • WASTE HEAT RECOVERY UNITS



    Used in the installations of cogeneration.



    They take advantage of the latent heat in the gases of combustion of engines, turbines, incinerators,...
  • HEAT EXCHANGERS



    - Vaporizer: used for small consumptions of steam in facilities of thermal oil.



    - Interaccumulator waters down warmly: warm water tank sanitary in facilities of thermal fluid.



    - Interchanger oil - oil: warming of vegetable(plant) oils with thermal oil.

Our Christmas present

According with the success of the thematic of the last posts and the dates in which we are, we want to do a gift to you.

Following with our policy to share the knowledge, we have the pleasure to announce to you that we have put at the disposal of all you in our Website and concretely in the section of Technology, some formulas of calculation that can be useful for the future professionals in our sector of activity and also for our clients.

Also, we are thinking especially about our readers who are not engineering specialists: When they will need a heating generator for a thermal fluid circuit, they will be able to have a priori more comprehensible specific parameters, which they will receive from their suppliers.

We hope that this gift serves to make easy your future decisions of investment in heating systems. As Goethe said: “The love and the joy are wings for the new projects”.

Merry Christmas from PIROBLOC. Read More!

Our third anniversary

Three years ago, we published the first blog in google.

Lapsed that time, we have been object of a study next to other companies, we have received some consultations and we hope to have contributed with enough information on the technology that we develop, technical points of view and to have helped to decide on the convenience or not of its use in the investment projects of the people in charge of industrial plants.

By our part, we are thankful for the visits to our blog and about the received comments of the readers.

PIROBLOC born in the secondary sector and oriented its activity to the national market as well as to the foreign one, using this blog and other tools at disposal today for everybody, to continue transferring knowledge and technology to which wants to continue reading us.

We hope to be able to continue receiving your visits and your consultations, to improve and to grow in all the industrial sectors in which our long experience is a guarantee. Read More!

Election of the fuel for your process

At the beginning of its activity or during the same, a company must choose the fuel whereupon to work in its processes and other many they are submitted to the provision that they have at disposal.

The factors that affect the election of the fuel are different according to the point of view from which they are studied:
  • The availability in the zone.
  • The initial investment to realise:
    • The price of the burner, being the most expensive dual burners (able to burn 2 or most fuels), burner of H.F.O. (heavy fuel oil); those of gas and finally those of light oil.
    • The necessary cost of the pipeline of fuel provision till the burner, vessels, safety measures, etc. This point has major incidence that the previous one.
  • The considered consumption derivative of the activity: The election in this case, can depend on the hours of process and the calorific necessity of the same. The ideal is to do a comparison by unit of calorific power like kilocalories or thermia (1000 kcal) necessary in its process: The product of the multiplication by the PCI of each fuel and the cost in kg, liter or m3 of each, will give to you the cost by thermia and therefore, what fuel is the most convenient for your activity. In the following table appear the PCI's of the more current conventional fuels:
Type of fuel Calorific power
Inferior Superior
Natural gas 9.270 kcal/m3
Liquefied petroleum gases
Comercial Propane
11.082 Kcal/Kg
12.052 Kcal/Kg.
Methane 5.500 kcal/m3
Commercial butane 10.938 Kcal/Kg 11.867Kcal/Kg.
Light oil type C 10.100 kcal/kg
Biodiesel It depends on his composition
H. Fuel oil 9.400 kcal/kg

You can visit a web about Liquefied petroleum gases in which there is an example about the equivalence of 1 kg of propane in reference to the energy provided by:
1,24 ms ³ of natural gas;
1,20 lt. of H. fuel-oil;
3 ms ³ of citizen gas;
1,30 lt. of light oíl;
3 to 6 kg of firewood (generic data);
14 kWh of electricity;
to 2 kg of coal.
  • On the basis of the tariffs that propose to you: With an approximate calculation of the consumption you will obtain the supply tariff of your gas and electricity suppliers, whose prices are very tie to the zone in which you are located.
  • On the basis of the maintenance: The burners with gaseous fuels always have a simpler maintenance than those of light oil and heavy fuel-oil (being used these last ones in boilers and furnaces of major heat ratings), because gases have a cleaner combustion.
  • On the basis of the environment: Companies located in cities, laboratories or other companies of nonpolluting character, are forced in many occasions to use the electricity to avoid emissions of CO2 to the atmosphere.
Read More!

Comparison between thermal fluid and steam

In previous posts we informed on the thermal fluid transmitters that can be used in an industrial installation. In this blog we want to make a comparison between the use of the thermal fluid versus the steam, both perhaps the most extended systems world-wide.

The requirements for the steam facilities are more restrictive than those of thermal fluid:
  • Steam boilers of a certain size and water volume have to be installed in a separate boiler room. In many countries the boiler room cannot be located within the main building or production site, but has to be separated at a certain minimum distance. Moreover, protection walls of such boiler room have to be of a minimum thickness, depending on the category of the boiler.
  • Water treatment is an absolute requirement for every type of steam boiler, whether of the coil type, water tube or fire tubes. Water treatment consists of a water softening plant (which should be a twin system in most of the cases) in combination with a chemical treatment of pH control and oxygen scavenger. A water softener “Twin” system consists of two cylinders to hold the resin in order to allow a regeneration of one column whilst the other resin column remains in service. A twin softener is an absolute must in production plants with a continuous operating cycle of 24/24 h.
  • Oxygen removal and pH control can be done by means of a chemical dosing system (dosing pump with dosing tank). With some type of boilers, especially of the coil type, special care has to be given during “stand-still” periods. If no measures have been taken to keep the coil either completely dry or completely filled by means of a time controlled “post-run” system, the risk of oxygen corrosion during standstill period is very high. (Note: Post-run means that the water pump has to remain in operation to keep the coil filled with water whilst the system cools down, in order to prevent air pockets to be formed in the upper part of the heating coil which would introduce oxygen in the heating coil and cause a typical form of “pit corrosion”).
  •  With too much concentration of TDS (Total Dissolved Solids), a carry over of chemicals will take place. Too high concentration of dissolved solids (example over 3.000 mg/l) can be caused either when blow down periods are not being strictly adhered to or during “peak-loads” which demand momentarily more steam than the average nominal capacity of the boiler size. This carry-over will result into wet steam and the chemicals which will remain in “wet steam” can block steam traps, steam regulating valves etc. Hence, high maintenance costs and waste of energy in case steam traps do not function properly and do not shut off properly.
  • Some more details are referred to in the section “Corrosion” hereafter. Especially in fire tube boilers, because of the larger water content, explosion risk remains despite added automation on modern boilers.

Efficiency

The thermal fluid does not require any special treatment once the installation has been filled up. Its life oscillates between 10 and 12 years. This means that the cost of this element is really insignificant.

The thermal fluid, which comes out of equipment after having heated it, will enter into the generator with only 1 or 2 ºC less temperature. This shows that the loss of heat during its way in the line is situated at the minimum.

There has to be taken into account, that the outcoming steam of a purge has an average temperature of 120 ºC, whereas when it reaches the tank of condensed it usually does not exceed 90 ºC, and in many occasions it does not even reach this low temperature. On the other hand it should also be taken into account, that there always remain a flow of steam in the purges which gets lost through evaporation and these calories are never more recovered.

Thermal fluid systems suffer none of the above-described losses.

Legal requirements

These are generators working WITHOUT HIGH PRESSURE. This fact exonerates them of the walls, distances to neighborhood, and all the other norms which have to be taken inTO account and accomplished for the steam type boilers. Thermal fluid boilers may be installed in any place, even just besides the manufacturing machines.

Corrosion

Neither the generator nor the pipeline suffer from wearing away, as the function is done with lubrication liquid, NOT CORROSIVE like water.

Maintenance

Any kind of dragging, such as for water, of salts, of oxides, or of any other indissoluble solids is not necessary. This means that nothing can affect the goodness of heat transmission through thermal oil. This type of installations are practically free of maintenance.

Fuel saving

When heating is done through thermal fluid, we are able to obtain a level of temperature regulation till ± 2 ºC in the machines. When using steam heating this is completely unthinkable, as the differences in a normal installation are situated around ± 10 ºC.

This is of course also a very important factor in saving fuel, as it allows organizing a very regular temperature average, without any fear that the quality of the product may get spoiled due to the ups and downs which could occur when treated with steam.

The sum of the related factors results on a fuel saving around a minimum 12 to 18% according to concrete data taken in facilities which are working for a long time to total satisfaction of our clients.

Technology

Another advantage when using thermal fluid, is that all problems concerning passing preferences, as usually they appear in steam installations, are completely cancelled: When working with steam all the machines, which are located nearer to the boilers, they will receive the full amount of flow which they need. Those machines which are at a greater distance very often have a lack of flow.

With the thermal fluid and through our system of ballast check valves we assure to each individual machine the whole quantity of necessary hot oil, ensuring a temperature stability.

Safety

No risk of explosion, because there is no high pressure inside and neither hot oil storage.

Cavitations do not appear in the recirculating pump of thermal oil.

In steam installations they may arise when the feeding water which is recovered from the condensed surpasses a temperature of 90 ºC, at that stage either it is cooled down with water entering in the line or part of the condensed are thrown away, but this last supposition is really absurd in view of the cost of the fuel.

With the details we have mentioned above, we intend to offer you a global view on the subject of the thermal fluid installations. However in order to get a more precise knowledge it is necessary to enter deeper in this kind of equipment, for this purpose we remain at your entire disposition. Read More!

Important aspects about ISO 9001

In our previous article about how it repels in the client the certificate of quality ISO 9001, we commented several aspects that we will extend next.

We have observed an important interest by this subject and for this reason we will deepen in the following aspects that we consider of great relevance in the norm ISO 9001:
  1. Planning of the production of the product: PIROBLOC plans and develops the necessary processes for the accomplishment of the product. These processes determine:
    1. Objectives of the quality and the requirements for the product.
    2. Required activities of verification, validation, pursuit, measurement, inspection and tests.
    3. Registry of all the activities to demonstrate the fulfill of all the requirements.
Read More!